- Página de inicio
- Generadores
- Multiquip Generadores
Optimizar ResultadosMultiquip Generadores de segunda mano en venta | |
Medidor: 46 hrs Pennsylvania (Dist: 415 mi) 2018 US EPA Label, Honda GX630 2 Cylinder Gasoline Engine, 120 V / 240 V Rated Voltage, 240 V & 120 V Receptacles, Bottom Mounted Fuel Tank Pennsylvania (Dist: 415 mi) Tier 3, 2019 US EPA Label, Honda GX340 2 Cylinder Gasoline Engine, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles Medidor: Consulte el informe Florida (Dist: 797 mi) 125 kVA/100 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 72 kVA,/72 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo DB-1381J3 Generator, 2014 US EPA Label, John Deere 4045HFG93 4 Cylinder 4.5 L Diesel Engine, T/A Trailer, Lunette Ring, Surge Brakes Pennsylvania (Dist: 415 mi) 2018 US EPA Label, Honda GX160 2 Cylinder Gasoline Engine, /2.5 kW, Rated Single Phase Output, 120 V Rated Voltage, 120 V Receptacles Medidor: 1,375 hrs North Carolina (Dist: 343 mi) 2018 US EPA Label, Honda GX340 1 Cylinder Gasoline Engine, 120 V / 240 V Rated Voltage, 240 V & 120 V Receptacles Medidor: 2,561 hrs Texas (Dist: 922 mi) 45 kVA/36 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 26 kVA,/26 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo Vietnam DH-0480I(T4) Generator, 2015 US EPA Label, Isuzu BP-4LE2X 4 Cylinder Diesel Engine, T/A Trailer, Ball Hitch Medidor: 15,227 hrs Florida (Dist: 797 mi) 125 kVA/100 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 72 kVA,/72 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo DB-1381J3 Generator, 2014 US EPA Label, John Deere 4045HFG93 4 Cylinder 4.5 L Diesel Engine, T/A Trailer, Lunette Ring, Surge Brakes Medidor: 17,899 hrs Texas (Dist: 930 mi) 70 kVA/56 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Bottom Mounted Fuel Tank, Denyo DH-0750i 70 kVA Generator, Tier 4, 2017 US EPA Label, Isuzu BR-4JJ1X 75 kW 3.0 L Diesel Engine, Requires Diesel Exhaust Fluid, T/A Trailer, Lunette Ring, Surge Brakes Medidor: 10,445 hrs Louisiana (Dist: 803 mi) 2015 US EPA Label, John Deere 6068HFG09 6 Cylinder 6.8 L Diesel Engine, Positive Air Shutoff, 220 kVA/ Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 240 V & 120 V Receptacles, Bottom Mounted Fuel Tank, T/A Trailer, Lunette Ring, Electric Brakes Medidor: 13,288 hrs Florida (Dist: 797 mi) 70 kVA/56 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo DH-0750J Generator, Tier 4, 2014 US EPA Label, John Deere 4045HFG92 4 Cylinder 4.5 L Diesel Engine, T/A Trailer, Surge Brakes Medidor: 16,148 hrs Nevada (Dist: 1,764 mi) 2015 US EPA Label, Isuzu 4 Cylinder Diesel Engine, 125 kVA/100 kW Rated 3 Phase Output, 240 V / 280 V Rated Voltage, 72 kVA,/72 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Bottom Mounted Fuel Tank, T/A Trailer, Lunette Ring Medidor: 687 hrs California (Dist: 2,049 mi) 2017 US EPA Label, Honda GX340 1 Cylinder Gasoline Engine, 120 V / 250 V Rated Voltage, 240 V & 120 V Receptacles Medidor: 315 hrs Connecticut (Dist: 523 mi) /20 kW, Rated Single Phase Output, 120 V / 240 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo Vietnam Co., Ltd. DF-0277i 20 kW Generator, Tier 4, 2020 US EPA Label, CARB Compliant, Isuzu 4LE2T 4 Cylinder 30 kW 2.17 L Diesel Engine, S/A Trailer, Lunette Ring Medidor: 3,493 hrs California (Dist: 2,096 mi) 25 kVA/20 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 14.4 kVA,/14.4 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Tier 4, Isuzu 4 Cylinder Diesel Engine, S/A Trailer, Lunette Ring Medidor: 289 hrs California (Dist: 2,049 mi) 2018 US EPA Label, Honda 1 Cylinder Gasoline Engine, 120 V / 240 V Rated Voltage, 240 V & 120 V Receptacles Medidor: 1,477 hrs California (Dist: 2,096 mi) 25 kVA/20 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 14.4 kVA,/14.4 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Tier 4, Isuzu 4 Cylinder Diesel Engine, S/A Trailer, Lunette Ring Medidor: 3,904 hrs California (Dist: 2,096 mi) 25 kVA/20 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 14.4 kVA,/14.4 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo Generator, Isuzu 4 Cylinder Diesel Engine, S/A Trailer, Lunette Ring Medidor: 322 hrs California (Dist: 2,049 mi) 2018 US EPA Label, Honda GX240 1 Cylinder Gasoline Engine, 120 V / 240 V Rated Voltage, 240 V & 120 V Receptacles Medidor: 1 hrs Saskatchewan (Dist: 1,135 mi) 2022 US EPA Label, Isuzu 4LE2T 4 Cylinder 37 kW 2.17 L Diesel Engine, 25 kVA/20 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 14.4 kVA,/14.4 kW, Rated Single Phase Output, 120 V / 240 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, S/A Trailer, Lunette Ring, Cold Weather Pkg Medidor: 18,475 hrs California (Dist: 1,993 mi) 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo DF-3300C Generator, Tier 4, 2016 US EPA Label, John Deere 6090HFG09 9.0 L Diesel Engine, Requires Diesel Exhaust Fluid, T/A Trailer, Lunette Ring, Electric Brakes Medidor: 10,462 hrs California (Dist: 1,989 mi) 400 kVA/ Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo DF-4400I Generator, Tier 4, Isuzu BQ-6WG1X 6 Cylinder 382 kW 15.6 L Diesel Engine, Requires Diesel Exhaust Fluid, T/A Trailer, Lunette Ring, Surge Brakes Medidor: 15,413 hrs California (Dist: 1,989 mi) 70 kVA/ Rated 3 Phase Output, 480 V / 240 V Rated Voltage, 40 kVA,/ Rated Single Phase Output, 240 V 120 V Rated Voltage, Tier 4, Isuzu BR-4JJ1X 4 Cylinder 2.99 L Diesel Engine, Requires Diesel Exhaust Fluid, T/A Trailer, Lunette Ring, Surge Brakes Medidor: 3,121 hrs New Jersey (Dist: 466 mi) 25 kVA/20 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 14.4 kVA,/14.4 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo DF-0270I2 Generator, Tier 4, 2015 US EPA Label, Isuzu 4LE2T 4 Cylinder 2.17 L Diesel Engine, S/A Trailer, Lunette Ring Medidor: 1,650 hrs Ohio (Dist: 84 mi) US EPA Label, Isuzu BJ-4JJ1X 4 Cylinder 73 kW Diesel Engine, 45 kVA/36 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 26 kVA,/26 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Bottom Mounted Fuel Tank, T/A Trailer, Ball Hitch, Surge Brakes Medidor: 9,131 hrs Michigan (Dist: 236 mi) 70 kVA/ Rated 3 Phase Output, 240 V / 480 V / 120 V Rated Voltage, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo DB-0831I2 70 kVA Generator, Tier 2, 2015 US EPA Label, Isuzu FF-4BG1T 4 Cylinder 73.5 kW 4.3 L Diesel Engine, T/A Trailer, Ball Hitch, Surge Brakes Medidor: 3,025 hrs Arizona (Dist: 1,667 mi) 2016 US EPA Label, Isuzu BP-4LE2X 4 Cylinder 49 kW Diesel Engine, 45 kVA/36 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 26 kVA,/26 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Bottom Mounted Fuel Tank, T/A Trailer, Lunette Ring Medidor: 7,756 hrs Florida (Dist: 832 mi) 70 kVA/56 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo DH-0750J Generator, 2014 US EPA Label, John Deere 4045HFG92 4 Cylinder 4.5 L Diesel Engine, T/A Trailer, Lunette Ring, Surge Brakes Medidor: 5,018 hrs Illinois (Dist: 285 mi) Tier 4, Isuzu 4 Cylinder 2.7 L Diesel Engine, 45 kVA/36 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 26 kVA,/26 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 230 V & 400 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, T/A Trailer, Ball Hitch, Surge Brakes Medidor: 7,194 hrs New Jersey (Dist: 407 mi) 2013 US EPA Label, John Deere 4045HFG92A 4 Cylinder 4.5 L Diesel Engine, 70 kVA/56 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, Bottom Mounted Fuel Tank, T/A Trailer, Lunette Ring Medidor: 1,500 hrs Florida (Dist: 959 mi) 25 kVA/20 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 14.4 kVA,/14.4 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Bottom Mounted Fuel Tank, Denyo DF-0270I2 Generator, 2016 US EPA Label, Isuzu 4LE2T 4 Cylinder 2.17 L Diesel Engine, S/A Trailer, Lunette Ring Medidor: 3,714 hrs California (Dist: 2,096 mi) 45 kVA/36 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 26 kVA,/26 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo DH-0480I(T4) 36 kW Generator, 2016 US EPA Label, Isuzu BP-4LE2X 4 Cylinder 49 kW Diesel Engine, T/A Trailer, Lunette Ring, Surge Brakes Medidor: 6,947 hrs Alabama (Dist: 698 mi) 2013 US EPA Label, John Deere 4045HFG92 4 Cylinder 4.5 L Diesel Engine, 70 kVA/56 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, T/A Trailer, Lunette Ring, Electric Brakes Medidor: 9,353 hrs Texas (Dist: 934 mi) 70 kVA/56 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, 2014 US EPA Label, John Deere 4 Cylinder 4.5 L Diesel Engine, T/A Trailer, Lunette Ring, Surge Brakes New Jersey (Dist: 464 mi) 2014 US EPA Label, John Deere 4045HF 4.5 L Diesel Engine, 70 kVA/56 kW Rated 3 Phase Output, / 480 V / 240 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, T/A Trailer, Lunette Ring, Surge Brakes Medidor: 5,662 hrs Texas (Dist: 1,002 mi) 2013 US EPA Label, John Deere 4045HFG92 4 Cylinder 4.5 L Diesel Engine, 70 kVA/56 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, T/A Trailer, Lunette Ring, Surge Brakes Massachusetts (Dist: 609 mi) US EPA Label, CARB Compliant, Cummins QSL9-G3 6 Cylinder 270 hp 8.9 L Diesel Engine, 300 kVA/ Rated 3 Phase Output, 240 V / 480 V Rated Voltage, Sound Attenuated, Bottom Mounted Fuel Tank, T/A Trailer, Lunette Ring, Electric Brakes Medidor: Consulte el informe Texas (Dist: 930 mi) 45 kVA/36 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 26 kVA,/26 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo DH-0480I 36 kW Generator, 2014 US EPA Label, Isuzu BP-4LE2X 4 Cylinder 49 kW 2.2 L Diesel Engine, T/A Trailer, Lunette Ring, Surge Brakes Medidor: 5,175 hrs Wisconsin (Dist: 336 mi) US EPA Label, Isuzu 4 Cylinder Diesel Engine, 25 kVA/20 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 14.4 kVA,/14.4 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 230 V & 400 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, S/A Trailer, Lunette Ring Medidor: 6,462 hrs Minnesota (Dist: 630 mi) Isuzu 4LE2X 2.1 L Diesel Engine, 45 kVA/36 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 26 kVA,/26 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, T/A Trailer, Lunette Ring, Surge Brakes Medidor: 9,077 hrs Louisiana (Dist: 802 mi) Tier 4, 2013 US EPA Label, John Deere 4045HFG92A 4 Cylinder 4.5 L Diesel Engine, 70 kVA/56 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, T/A Trailer, Ball Hitch Medidor: 8,026 hrs Texas (Dist: 1,179 mi) 2014 US EPA Label, Isuzu bp-4le2x Diesel Engine, 45 kVA/36 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 26 kVA,/26 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, T/A Trailer, Surge Brakes Medidor: 10,963 hrs Texas (Dist: 1,002 mi) 2014 US EPA Label, John Deere 4045HFG92 4 Cylinder 4.5 L Diesel Engine, 70 kVA/56 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, T/A Trailer, Lunette Ring, Surge Brakes Medidor: 11,662 hrs Louisiana (Dist: 802 mi) Tier 4, 2013 US EPA Label, John Deere 4045HFG92A 4 Cylinder 4.5 L Diesel Engine, 70 kVA/56 kW Rated 3 Phase Output, 480 V / 240 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, T/A Trailer, Lunette Ring Medidor: 350 hrs Texas (Dist: 1,194 mi) Tier 4, 2014 US EPA Label, Isuzu BP-4LE2X 4 Cylinder 49 kW 2.17 L Diesel Engine, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, T/A Trailer, Surge Brakes Medidor: 12,513 hrs Louisiana (Dist: 888 mi) Tier 4, 2013 US EPA Label, John Deere 4045HFG92 4 Cylinder 56 kW 4.5 L Diesel Engine, 70 kVA/56 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, T/A Trailer, Lunette Ring, Surge Brakes, External Fuel Connections Medidor: 6,833 hrs Colorado (Dist: 1,258 mi) 70 kVA/40 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 70 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo DB-0831J 40 kW Generator, 2000 US EPA Label, John Deere 4 Cylinder Diesel Engine, T/A Trailer, Lunette Ring, Surge Brakes Medidor: 6,189 hrs California (Dist: 1,967 mi) 70 kVA/56 kW Rated 3 Phase Output, 480 V / 240 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Denyo DH-07500 Generator, Tier 4, 2013 US EPA Label, John Deere 4045 4.5 L Diesel Engine, T/A Trailer, Lunette Ring, Surge Brakes Medidor: 11,371 hrs California (Dist: 1,967 mi) Tier 4, 2014 US EPA Label, John Deere 4045 Diesel Engine, 70 kVA/56 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 40 kVA,/40 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, T/A Trailer, Lunette Ring Medidor: 23,199 hrs California (Dist: 2,087 mi) Isuzu BB-4JB1T 4 Cylinder 55 hp 3.05 L Diesel Engine, 45 kVA/36 kW Rated 3 Phase Output, 240 V / 120 V Rated Voltage, 26 kVA,/26 kW, Rated Single Phase Output, 240 V / 480 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, T/A Trailer, Lunette Ring, Surge Brakes British Columbia (Dist: 2,073 mi) Isuzu 4 Cylinder Diesel Engine, 25 kVA/20 kW Rated 3 Phase Output, 240 V / 280 V Rated Voltage, S/A Trailer, Lunette Ring Illinois (Dist: 267 mi) Illinois (Dist: 303 mi) |